Table of Contents
- 1. Product Overview
- 1.1 General Description
- 1.2 Key Features
- 1.3 Applications
- 2. Technical Parameter Analysis
- 2.1 Electrical and Optical Characteristics (Ts=25°C)
- 2.2 Absolute Maximum Ratings
- 3. Binning System
- 3.1 Color Temperature Bins
- 3.2 Luminous Flux Bins
- 4. Performance Curves Analysis
- 4.1 Forward Voltage vs. Relative Intensity
- 4.2 Ambient Temperature vs. Relative Intensity
- 4.3 Central Surface Temperature vs. Relative Intensity
- 4.4 Forward Voltage vs. Temperature
- 4.5 Central Surface Temperature vs. Forward Current
- 4.6 Radiation Diagram
- 4.7 Chromaticity Coordinate vs. Temperature
- 4.8 Spectrum Distribution
- 5. Mechanical and Packaging Information
- 5.1 Package Dimensions
- 5.2 Suction Box Dimensions
- 5.3 Label Specification
- 6. Soldering and Assembly Guidelines
- 6.1 Handling Precautions
- 6.2 Moisture Sensitivity and Storage
- 6.3 Cleaning
- 7. Packaging and Ordering Information
- 7.1 Packaging Quantity
- 7.2 Reliability Test Items
- 7.3 Failure Criteria
- 8. Application Design Considerations
- 9. Technical Advantages
- 10. Frequently Asked Questions
- 11. Application Examples
- 12. Working Principle
- 13. Development Trends
- LED Specification Terminology
- Photoelectric Performance
- Electrical Parameters
- Thermal Management & Reliability
- Packaging & Materials
- Quality Control & Binning
- Testing & Certification
1. Product Overview
1.1 General Description
The product is a white LED fabricated using a blue chip and phosphor conversion. Package dimensions: 12mm x 28mm x 2.3mm. It features an integrated package design and 360° full-angle luminescence, suitable for spot welding processes. Moisture sensitivity level: Level 5. RoHS compliant.
1.2 Key Features
- Integrated Package: combines chip and phosphor in a compact form.
- 360° Full Angle Luminescence: emits light evenly in all directions.
- Suitable for Spot Welding Process: compatible with automated assembly.
- Moisture Sensitivity Level 5: requires handling within 24 hours after opening.
- RoHS Compliant: free of hazardous substances.
1.3 Applications
Primary applications include LED halogen lamps (retrofit), decorative lighting, indoor illumination, and general lighting. The wide viewing angle and high CRI make it suitable for residential and commercial environments.
2. Technical Parameter Analysis
2.1 Electrical and Optical Characteristics (Ts=25°C)
| Parameter | Symbol | Condition | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Forward Voltage | Vf | AC230V | 225 | - | 235 | V |
| Luminous Flux | Φ | AC230V | 300 | - | 500 | lm |
| Viewing Angle | 2θ1/2 | AC230V | - | - | 360 | deg |
| Color Rendering Index | Ra | AC230V | 80 | - | - | / |
| R9 | R9 | AC230V | 0 | - | - | / |
| Power | P | AC230V | 2.8 | 3.1 | 3.4 | W |
The LED is designed to operate at 230V AC mains frequency (60Hz). The forward voltage range is 225-235V. Luminous flux varies from 300 to 500 lumens, depending on bin. The viewing angle is 360°, providing uniform light distribution. Color rendering index is at least 80, with R9 >= 0, ensuring good color reproduction for most applications. Power consumption is between 2.8W and 3.4W, making it energy-efficient.
2.2 Absolute Maximum Ratings
| Parameter | Symbol | Rating | Unit |
|---|---|---|---|
| Power Dissipation | PD | 3.73 | W |
| Frequency | Hz | 60 | Hz |
| Electrostatic Discharge (HBM) | ESD | 2000 | V |
| Operating Temperature | TOPR | -40 ~ +85 | °C |
| Storage Temperature | TOPR | -40 ~ +85 | °C |
| Junction Temperature | TJ | 125 | °C |
These ratings must not be exceeded during operation. Power dissipation is limited to 3.73W. The LED is rated for 2000V ESD (HBM). Operating and storage temperature range from -40°C to +85°C, with maximum junction temperature of 125°C. Above the maximum ratings may cause permanent damage.
3. Binning System
3.1 Color Temperature Bins
The LED series is available in multiple color temperatures: 2200K, 2400K, 2700K, 3000K, 4000K, 5000K, 6500K. Each CCT has multiple lumen bins. For example, 2700K has bins Rank430 (430-460lm), Rank480 (450-510lm), etc. The CIE chromaticity coordinates are precisely defined for each bin. Refer to the CIE diagram and coordinate tables in the specification for detailed bin boundaries.
3.2 Luminous Flux Bins
Total luminous flux range is 300-500lm at AC230V. Within each CCT, bins are categorized by flux ranges (e.g., 430-460lm, 450-510lm, 460-520lm, 470-530lm). Customers can specify desired bin code for tighter performance consistency.
4. Performance Curves Analysis
The following typical curves illustrate the LED behavior under various conditions.
4.1 Forward Voltage vs. Relative Intensity
As forward voltage increases from 200V to 300V, relative intensity rises to a maximum and then saturates. The optimal operating region is around 225-235V.
4.2 Ambient Temperature vs. Relative Intensity
Relative luminous flux decreases with rising ambient temperature. At 100°C, the flux drops to about 70% of the value at 25°C. Thermal management is crucial for maintaining light output.
4.3 Central Surface Temperature vs. Relative Intensity
Similar trend: as the central surface temperature increases, relative intensity decreases. The LED should be kept below 85°C for optimal performance.
4.4 Forward Voltage vs. Temperature
Forward voltage shows a negative temperature coefficient: it decreases linearly with rising temperature. At 100°C, Vf is approximately 227V compared to 235V at 25°C.
4.5 Central Surface Temperature vs. Forward Current
The forward current (mA) decreases as temperature increases, indicating that the LED driver must compensate for thermal effects.
4.6 Radiation Diagram
The radiation pattern shows uniform emission in all horizontal directions, confirming the 360° viewing angle. Intensity variation is minimal.
4.7 Chromaticity Coordinate vs. Temperature
CIE x and y coordinates shift slightly with temperature, but remain within specified bin boundaries for the rated range (-40 to +85°C).
4.8 Spectrum Distribution
The spectrum consists of a blue peak around 450nm and a broad yellow phosphor emission centered at ~580nm, resulting in white light.
5. Mechanical and Packaging Information
5.1 Package Dimensions
Package size: 12mm (length) x 28mm (width) x 2.3mm (height). Tolerances ±0.5mm unless otherwise noted. The LED features two leads for electrical connection. A reversed drawing shows the correct polarity. ESD caution symbol is marked on the package.
5.2 Suction Box Dimensions
The suction box used for packaging has dimensions 750mm x 800mm (subject to tolerance ±0.1mm). Each box contains 50 pieces.
5.3 Label Specification
Labels include: Part Number (P/N), Spec Number (S/N), Lot Number (L/N), Bin Code, Chromaticity Bin (X/Y), Luminous Flux (Φ), Forward Voltage (Vf), Color Rendering Index (Ra), Quantity (QTY), and Date. Barcode may be included.
6. Soldering and Assembly Guidelines
6.1 Handling Precautions
- Handle components by the sides using tweezers; do not touch the silicone lens directly to avoid damaging internal circuitry.
- Do not apply reverse voltage; circuit must allow only forward voltage when switching on/off.
- Use current-limiting resistors; even small voltage variations can cause large current changes and burn out LEDs.
- Thermal design is critical: ensure adequate heat dissipation to prevent brightness reduction and color shift.
- Avoid exposure to high sulfur, chlorine, and bromine environments (sulfur <100ppm, single Br<900ppm, single Cl<900ppm, total Br+Cl<1500ppm).
- VOCs from fixture materials can penetrate silicone and cause discoloration; test materials for compatibility.
6.2 Moisture Sensitivity and Storage
- Before opening aluminum bag: store at ≤30°C, ≤75%RH, within 1 year from date.
- After opening: use within 24 hours at ≤30°C, ≤60%RH.
- If exceeded, bake at 60±5°C for >24 hours.
- Do not use if packaging is damaged or inflated; contact sales support.
6.3 Cleaning
If cleaning is necessary, isopropyl alcohol is recommended. Do not use solvents that may dissolve the package. Ultrasonic cleaning is not recommended as it may damage the LED.
7. Packaging and Ordering Information
7.1 Packaging Quantity
Standard packaging: 50 pieces per box.
7.2 Reliability Test Items
| Test Item | Condition | Duration | Ac/Re |
|---|---|---|---|
| Thermal Shock | -40°C/15min ↔ 100°C/15min | 1000 cycles | 0/1 |
| Switching Test | 25°C, On/Off 2.5min | 2500 cycles | 0/1 |
| Life Test (Room Temperature) | Ta=25°C, AC230V | 1000 hrs | 0/1 |
| High Temperature High Humidity Life Test | 60°C/90%RH, AC230V | 500 hrs | 0/1 |
7.3 Failure Criteria
After testing, the device is considered failed if power consumption exceeds ±10% of specification, or luminous flux drops below 70% of initial value.
8. Application Design Considerations
When designing with this G9 LED filament, consider the following: (1) Use a constant voltage AC driver with appropriate current limiting. (2) Ensure proper heatsinking; the junction temperature must not exceed 125°C. (3) For dimmable applications, select compatible dimmers designed for AC LEDs. (4) Account for inrush current. (5) The LED is non-spectroscopic product; over 90% of units in a batch meet the electrical/optical parameters. (6) Avoid mechanical stress on the filament.
9. Technical Advantages
Compared to traditional LED filament bulbs, this product offers an integrated package, 360° light distribution, simplified assembly (spot welding), and wide color temperature range. The high CRI (Ra≥80) and good R9 value ensure vivid color rendering. The moisture barrier bag and MSL 5 rating guarantee reliability during storage and soldering.
10. Frequently Asked Questions
Q: Why is the operating voltage AC230V? A: This LED is designed to work directly on mains AC, simplifying driver design. Q: How to ensure the 360° viewing angle? A: The filament-shaped package emits light from all sides. Q: What if the device is exposed to humidity? A: Follow the baking instructions to dry before use. Q: Can I use a DC driver? A: The specification is based on AC; using DC may affect performance. Q: What is the lifespan? A: The reliability tests show 1000 hours at room temperature; actual lifetime depends on thermal management and operating conditions.
11. Application Examples
Typical application: replacing G9 halogen bulbs in decorative chandeliers, wall sconces, and under-cabinet lighting. The 360° emission and small size make it ideal for retrofitting existing fixtures. Multiple units can be combined for higher lumen output.
12. Working Principle
The LED uses a blue InGaN chip that emits blue light (peak ~450nm). A yellow phosphor (often YAG:Ce) converts part of the blue light into broader yellow emission. The combination of blue and yellow produces white light. Different phosphor compositions achieve different correlated color temperatures (CCT) from warm white (2200K) to cool white (6500K).
13. Development Trends
Future trends for LED filaments include higher efficacy (over 200 lm/W), even higher CRI (Ra>95), better thermal performance, and reduced size. Integration with smart control (dimming, color tuning) is also expected. The G9 form factor will continue to evolve for better compatibility with existing fixtures.
LED Specification Terminology
Complete explanation of LED technical terms
Photoelectric Performance
| Term | Unit/Representation | Simple Explanation | Why Important |
|---|---|---|---|
| Luminous Efficacy | lm/W (lumens per watt) | Light output per watt of electricity, higher means more energy efficient. | Directly determines energy efficiency grade and electricity cost. |
| Luminous Flux | lm (lumens) | Total light emitted by source, commonly called "brightness". | Determines if the light is bright enough. |
| Viewing Angle | ° (degrees), e.g., 120° | Angle where light intensity drops to half, determines beam width. | Affects illumination range and uniformity. |
| CCT (Color Temperature) | K (Kelvin), e.g., 2700K/6500K | Warmth/coolness of light, lower values yellowish/warm, higher whitish/cool. | Determines lighting atmosphere and suitable scenarios. |
| CRI / Ra | Unitless, 0–100 | Ability to render object colors accurately, Ra≥80 is good. | Affects color authenticity, used in high-demand places like malls, museums. |
| SDCM | MacAdam ellipse steps, e.g., "5-step" | Color consistency metric, smaller steps mean more consistent color. | Ensures uniform color across same batch of LEDs. |
| Dominant Wavelength | nm (nanometers), e.g., 620nm (red) | Wavelength corresponding to color of colored LEDs. | Determines hue of red, yellow, green monochrome LEDs. |
| Spectral Distribution | Wavelength vs intensity curve | Shows intensity distribution across wavelengths. | Affects color rendering and quality. |
Electrical Parameters
| Term | Symbol | Simple Explanation | Design Considerations |
|---|---|---|---|
| Forward Voltage | Vf | Minimum voltage to turn on LED, like "starting threshold". | Driver voltage must be ≥Vf, voltages add up for series LEDs. |
| Forward Current | If | Current value for normal LED operation. | Usually constant current drive, current determines brightness & lifespan. |
| Max Pulse Current | Ifp | Peak current tolerable for short periods, used for dimming or flashing. | Pulse width & duty cycle must be strictly controlled to avoid damage. |
| Reverse Voltage | Vr | Max reverse voltage LED can withstand, beyond may cause breakdown. | Circuit must prevent reverse connection or voltage spikes. |
| Thermal Resistance | Rth (°C/W) | Resistance to heat transfer from chip to solder, lower is better. | High thermal resistance requires stronger heat dissipation. |
| ESD Immunity | V (HBM), e.g., 1000V | Ability to withstand electrostatic discharge, higher means less vulnerable. | Anti-static measures needed in production, especially for sensitive LEDs. |
Thermal Management & Reliability
| Term | Key Metric | Simple Explanation | Impact |
|---|---|---|---|
| Junction Temperature | Tj (°C) | Actual operating temperature inside LED chip. | Every 10°C reduction may double lifespan; too high causes light decay, color shift. |
| Lumen Depreciation | L70 / L80 (hours) | Time for brightness to drop to 70% or 80% of initial. | Directly defines LED "service life". |
| Lumen Maintenance | % (e.g., 70%) | Percentage of brightness retained after time. | Indicates brightness retention over long-term use. |
| Color Shift | Δu′v′ or MacAdam ellipse | Degree of color change during use. | Affects color consistency in lighting scenes. |
| Thermal Aging | Material degradation | Deterioration due to long-term high temperature. | May cause brightness drop, color change, or open-circuit failure. |
Packaging & Materials
| Term | Common Types | Simple Explanation | Features & Applications |
|---|---|---|---|
| Package Type | EMC, PPA, Ceramic | Housing material protecting chip, providing optical/thermal interface. | EMC: good heat resistance, low cost; Ceramic: better heat dissipation, longer life. |
| Chip Structure | Front, Flip Chip | Chip electrode arrangement. | Flip chip: better heat dissipation, higher efficacy, for high-power. |
| Phosphor Coating | YAG, Silicate, Nitride | Covers blue chip, converts some to yellow/red, mixes to white. | Different phosphors affect efficacy, CCT, and CRI. |
| Lens/Optics | Flat, Microlens, TIR | Optical structure on surface controlling light distribution. | Determines viewing angle and light distribution curve. |
Quality Control & Binning
| Term | Binning Content | Simple Explanation | Purpose |
|---|---|---|---|
| Luminous Flux Bin | Code e.g., 2G, 2H | Grouped by brightness, each group has min/max lumen values. | Ensures uniform brightness in same batch. |
| Voltage Bin | Code e.g., 6W, 6X | Grouped by forward voltage range. | Facilitates driver matching, improves system efficiency. |
| Color Bin | 5-step MacAdam ellipse | Grouped by color coordinates, ensuring tight range. | Guarantees color consistency, avoids uneven color within fixture. |
| CCT Bin | 2700K, 3000K etc. | Grouped by CCT, each has corresponding coordinate range. | Meets different scene CCT requirements. |
Testing & Certification
| Term | Standard/Test | Simple Explanation | Significance |
|---|---|---|---|
| LM-80 | Lumen maintenance test | Long-term lighting at constant temperature, recording brightness decay. | Used to estimate LED life (with TM-21). |
| TM-21 | Life estimation standard | Estimates life under actual conditions based on LM-80 data. | Provides scientific life prediction. |
| IESNA | Illuminating Engineering Society | Covers optical, electrical, thermal test methods. | Industry-recognized test basis. |
| RoHS / REACH | Environmental certification | Ensures no harmful substances (lead, mercury). | Market access requirement internationally. |
| ENERGY STAR / DLC | Energy efficiency certification | Energy efficiency and performance certification for lighting. | Used in government procurement, subsidy programs, enhances competitiveness. |