Select Language

LED Module 2835 18W Series - 582x24x6mm - 41.6-52.8V - 14.976-19.1W - CCT 2870-5250K Technical Data Sheet

High reliability 2835 LED module for panel lights, 360mA, 18W, CRI 80+, 582x24mm size, RoHS compliant. Suitable for mainstream LED panel light designs.
smdled.org | PDF Size: 1.0 MB
Rating: 4.5/5
Your Rating
You have already rated this document
PDF Document Cover - LED Module 2835 18W Series - 582x24x6mm - 41.6-52.8V - 14.976-19.1W - CCT 2870-5250K Technical Data Sheet

1. Product Overview

This LED module is designed according to the market mainstream of lamps and lanterns, ensuring easy matching and convenient assembly. It utilizes 2835 LED packages, offering high lighting efficiency, low heat generation, and is free of mercury, qualifying as an environmental-friendly cold light source. The module boasts high reliability and safety, with electrical parameters designed to align with mainstream LED power supplies. It is particularly suited for direct-lit (DLED) panel lights, providing uniform illumination and long operational life.

2. Technical Parameters Detailed Interpretation

2.1 Optical-Electrical Characteristics

At a solder point temperature (Ts) of 25°C and a forward current of 360mA, the module exhibits the following typical characteristics:

Four standard correlated color temperature (CCT) bins are available: 2870-3220K, 3220-3700K, 3700-4275K, and 4740-5250K, covering warm white to cool white.

2.2 Absolute Maximum Ratings

The module must not be operated beyond the following absolute maximum ratings at Ts=25°C to prevent damage:

2.3 Binning System

The module is sorted into bins based on CCT, luminous flux, and voltage. The naming convention (e.g., RF-MTD402T18-E1) encodes the module type (D: DLED), CCT (40: 3700-4275K), LED package type (2: 2835), CRI grade (H: 85≥T>80), power (18: 18W), emitting light way (E: top view), and version (1: first version). This systematic binning allows customers to select modules with tightly controlled parameters for consistent fixture performance.

3. Mechanical and Packaging Information

3.1 Outline Dimensions

The module has the following dimensions (tolerances are ±0.3mm unless noted):

The module is designed as a linear light bar with a 4P16S electrical configuration (4 parallel groups, 16 series LEDs per group? Or 4 pins, 16 series? The specification shows 4P16S connection diagram, indicating 4 parallel strings of 16 series LEDs). The PCB is a single-layer or multi-layer board with connector interface for easy integration.

3.2 Package Diagram

Modules are packed in blister boxes (trays) with a specific stacking method. Each blister box holds 20 modules (10 slots, 2 modules placed back-to-back per slot). A total of 8 loaded blister boxes plus one empty box (as a cover) are placed in a carton, yielding 160 modules per carton (20 modules/box × 8 boxes). The carton dimensions are provided in the full specification, and the carton is printed with handling symbols and identifiers.

4. Reliability and Material Testing

4.1 Reliability Tests

The module has undergone rigorous reliability testing with zero failures under the following conditions (sample size 6 per test):

These tests confirm the module's durability under typical and stressful environments.

4.2 Material Performance Tests

At Ta=25°C, the module's materials are tested to ensure quality:

5. Soldering and Handling Precautions

To ensure long-term reliability, adhere to the following guidelines:

6. Packaging and Ordering Information

6.1 Packaging Specifications

Modules are shipped in cartons containing 9 blister boxes (8 loaded + 1 empty cover). Each blister box holds 20 modules (10 slots × 2 modules back-to-back). The total quantity per carton is 160 modules. The stacking height for cartons is a maximum of 6 layers; adjust based on actual conditions to avoid damage.

6.2 Label Information

Each carton label includes the following fields: Customer Part Number, Part Number (P/N), Bin Code, Luminous Flux (LM), Voltage (VF), CCT, CRI, Quantity, Net Weight, and Date. This allows traceability and easy binning selection.

7. Application Recommendations

This LED module is optimized for direct-lit (DLED) panel lights. Typical applications include office lighting, commercial lighting, and general indoor illumination. When designing the luminaire, ensure proper heat sinking to keep the junction temperature below 115°C. The module's 4P16S configuration should be driven by a constant-current LED driver with a suitable current (360 mA typical) and voltage range (41.6–52.8 V). For optimal color uniformity, modules from the same CCT bin should be used within a single fixture.

8. Working Principle

These modules use 2835-sized SMD LEDs. When a forward current flows through the LED chip, electrons and holes recombine in the p-n junction, emitting photons. The emitted light's wavelength (color) depends on the semiconductor material (e.g., phosphor conversion for white LEDs). The module's high efficacy is achieved by using high-efficiency chips and optimized thermal management. The LEDs are arranged in a series-parallel matrix to achieve the desired voltage and current, ensuring uniform light output.

9. Development Trends

The trend in LED lighting modules is toward higher efficacy, smaller form factors, and improved color quality. This module's use of 2835 packages—a widely adopted mid-power package—balances cost and performance. Future developments may include higher CRI options (e.g., Ra > 90), tunable white capabilities, and integration with smart lighting controls. Additionally, environmental regulations continue to push for elimination of hazardous substances, which this module already complies with (RoHS, no mercury).

10. Frequently Asked Questions

Q1: What is the maximum current that can be applied to this module? The absolute maximum forward current is 360 mA continuous, with a peak of 650 mA (non-repetitive). For reliable operation, drive at 360 mA or lower.

Q2: Can the module be used in outdoor environments? The operating temperature range is -40°C to +85°C, but the module is not rated for outdoor use without additional moisture protection. Use in dry indoor environments is recommended.

Q3: How do I select the correct bin for my application? Choose CCT based on desired color temperature (e.g., 3500K for warm, 5000K for cool). Luminous flux bins indicate brightness; choose higher bins for higher output, but ensure the driver can handle the increased current. Voltage bins should match the driver's output range.

Q4: Is the module compatible with triac dimming? The module itself is a constant-current device. Dimming requires a compatible constant-current dimmable driver that adjusts forward current. Ensure the driver's minimum load is satisfied.

Q5: What is the expected lifetime? Based on the reliability tests, the module can exceed 50,000 hours of operation at rated current with L70 maintenance (30% lumen depreciation). Actual lifetime depends on thermal management and driver quality.

LED Specification Terminology

Complete explanation of LED technical terms

Photoelectric Performance

Term Unit/Representation Simple Explanation Why Important
Luminous Efficacy lm/W (lumens per watt) Light output per watt of electricity, higher means more energy efficient. Directly determines energy efficiency grade and electricity cost.
Luminous Flux lm (lumens) Total light emitted by source, commonly called "brightness". Determines if the light is bright enough.
Viewing Angle ° (degrees), e.g., 120° Angle where light intensity drops to half, determines beam width. Affects illumination range and uniformity.
CCT (Color Temperature) K (Kelvin), e.g., 2700K/6500K Warmth/coolness of light, lower values yellowish/warm, higher whitish/cool. Determines lighting atmosphere and suitable scenarios.
CRI / Ra Unitless, 0–100 Ability to render object colors accurately, Ra≥80 is good. Affects color authenticity, used in high-demand places like malls, museums.
SDCM MacAdam ellipse steps, e.g., "5-step" Color consistency metric, smaller steps mean more consistent color. Ensures uniform color across same batch of LEDs.
Dominant Wavelength nm (nanometers), e.g., 620nm (red) Wavelength corresponding to color of colored LEDs. Determines hue of red, yellow, green monochrome LEDs.
Spectral Distribution Wavelength vs intensity curve Shows intensity distribution across wavelengths. Affects color rendering and quality.

Electrical Parameters

Term Symbol Simple Explanation Design Considerations
Forward Voltage Vf Minimum voltage to turn on LED, like "starting threshold". Driver voltage must be ≥Vf, voltages add up for series LEDs.
Forward Current If Current value for normal LED operation. Usually constant current drive, current determines brightness & lifespan.
Max Pulse Current Ifp Peak current tolerable for short periods, used for dimming or flashing. Pulse width & duty cycle must be strictly controlled to avoid damage.
Reverse Voltage Vr Max reverse voltage LED can withstand, beyond may cause breakdown. Circuit must prevent reverse connection or voltage spikes.
Thermal Resistance Rth (°C/W) Resistance to heat transfer from chip to solder, lower is better. High thermal resistance requires stronger heat dissipation.
ESD Immunity V (HBM), e.g., 1000V Ability to withstand electrostatic discharge, higher means less vulnerable. Anti-static measures needed in production, especially for sensitive LEDs.

Thermal Management & Reliability

Term Key Metric Simple Explanation Impact
Junction Temperature Tj (°C) Actual operating temperature inside LED chip. Every 10°C reduction may double lifespan; too high causes light decay, color shift.
Lumen Depreciation L70 / L80 (hours) Time for brightness to drop to 70% or 80% of initial. Directly defines LED "service life".
Lumen Maintenance % (e.g., 70%) Percentage of brightness retained after time. Indicates brightness retention over long-term use.
Color Shift Δu′v′ or MacAdam ellipse Degree of color change during use. Affects color consistency in lighting scenes.
Thermal Aging Material degradation Deterioration due to long-term high temperature. May cause brightness drop, color change, or open-circuit failure.

Packaging & Materials

Term Common Types Simple Explanation Features & Applications
Package Type EMC, PPA, Ceramic Housing material protecting chip, providing optical/thermal interface. EMC: good heat resistance, low cost; Ceramic: better heat dissipation, longer life.
Chip Structure Front, Flip Chip Chip electrode arrangement. Flip chip: better heat dissipation, higher efficacy, for high-power.
Phosphor Coating YAG, Silicate, Nitride Covers blue chip, converts some to yellow/red, mixes to white. Different phosphors affect efficacy, CCT, and CRI.
Lens/Optics Flat, Microlens, TIR Optical structure on surface controlling light distribution. Determines viewing angle and light distribution curve.

Quality Control & Binning

Term Binning Content Simple Explanation Purpose
Luminous Flux Bin Code e.g., 2G, 2H Grouped by brightness, each group has min/max lumen values. Ensures uniform brightness in same batch.
Voltage Bin Code e.g., 6W, 6X Grouped by forward voltage range. Facilitates driver matching, improves system efficiency.
Color Bin 5-step MacAdam ellipse Grouped by color coordinates, ensuring tight range. Guarantees color consistency, avoids uneven color within fixture.
CCT Bin 2700K, 3000K etc. Grouped by CCT, each has corresponding coordinate range. Meets different scene CCT requirements.

Testing & Certification

Term Standard/Test Simple Explanation Significance
LM-80 Lumen maintenance test Long-term lighting at constant temperature, recording brightness decay. Used to estimate LED life (with TM-21).
TM-21 Life estimation standard Estimates life under actual conditions based on LM-80 data. Provides scientific life prediction.
IESNA Illuminating Engineering Society Covers optical, electrical, thermal test methods. Industry-recognized test basis.
RoHS / REACH Environmental certification Ensures no harmful substances (lead, mercury). Market access requirement internationally.
ENERGY STAR / DLC Energy efficiency certification Energy efficiency and performance certification for lighting. Used in government procurement, subsidy programs, enhances competitiveness.